Herunterladen Inhalt Inhalt Diese Seite drucken

Condensate Drain - EKOM DK50 2V/50 Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für DK50 2V/50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

17.5. Condensate drain

Compressors
Open the drain valve carefully and slowly. If the drain valve is opened too much,
it is accompanied by high noise level and uncontrolled jet of the accumulated
condensate
Risk of slipping on a wet floor in case of the collecting vessel overflow.
During regular operation, it is recommended to drain
condensate from the pressure tank.
 Switch off the compressor from the mains and
decrease air pressure in the device to max. 1
bar, e.g. by releasing air through the connected
device
 Install the hose with condensate drain valve
into the prepared bottle and drain condensate
from the tank by opening the drain valve (1)
Compressors can be equipped with Automatic condensate drain (AOK), which provides draining of
condensate from the air tank without the need of operator action (see chapter accesories).
Compressors with air dryer
Condensate from compressors with air dryers is
automatically drained into the condensate collection
vessel.
 Monitor the level in the vessel using the 1 l or 2
l markings (depending on the volume of the
vessel), and empty at least once a day.
NP-DK50 2V 50, 2x2V 110-A-4_03-2020-MD
Fig. 14: Condensate drain from the pressure tank
Fig. 15: Check of condensate collection vessel
48
PRODUCT MAINTENANCE
03/2020

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dk50 2x2v/110

Inhaltsverzeichnis