1.3.12 Safety guidelines for handling batteries
Danger

2. Description

1
Earth connection
2
Oil filler gauge plug
3
Oil draining screw
4
Fuel gauge
5
Fuel tank plug
1
Oil draining screw
2
Oil filler gauge plug
1
Fuel tap
1
Wheel
2
Air filter cover
1
Spark plug cap

3. Preparation before use

3.1. Positioning the generating set for operation
Choose a site that is clean, well ventilated and sheltered from bad weather.
Place the generating set on a flat, horizontal surface which is firm enough to prevent the set sinking down (under no circumstances
should the set tilt in any direction by more than 10°).
Store the additional supplies of oil and fuel within close proximity, whilst maintaining a certain distance for safety.
3.2. Earthing the generating set
Danger
To connect the set to the ground: Attach a 10 mm
driven 1 meter into the ground.

3.3. Checking the oil level

Before starting up the generating set, always check the engine oil level.
Top up with the recommended oil (see § Specifications) using a funnel, up to the upper limit on the dipstick.
Allow the generating set to cool down for at least 30 minutes before checking the oil level.
Important
Remove the oil filler cap-dipstick (fig. A - no. 2 & fig. B - no. 2) and wipe it.
Replace the oil filler cap-dipstick and pull it out again.
Check the level visually. It should be within the upper limit (fig. B - no. 3) and the lower limit (fig. B - no. 4) on the dipstick. Correct
as required.
Replace the oil filler cap-dipstick.
Wipe off excess oil with a clean cloth and check that there are no leaks.
Never leave the battery close to a flame or fire.
Use only insulated tools.
Never use sulphuric acid or acid water to top up the electrolyte level.
6
Fuel tap
7
Air filter
8
Choke
9
Ignition key
10
Recoil starter handle
3
Upper limit of gauge
4
Lower limit of gauge
2
Fixing clamps
3
Filtration elements nut
4
Paper element
2
Spark plug
The generating sets supply electrical current when in operation: risk of electrocution.
Connect the generating set to the ground at each use.
2
copper wire to the set's earth connection and to a galvanised steel earthing rod
Figure A
Figure B
Figure C
Figure D
Figure E
11
Circuit breakers
12
Electrical sockets
13
Starter battery
14
Exhaust silencer
15
Working hours counter
5
Oil filter
3
Fuel filter
5
Foam element