3.3 Installation:
- Only professionals are allowed to conduct the installation work. Moreover, they shall read and follow the operation
instructions below carefully to prevent machine damage or injuries.
- Only authorized technicians are allowed to install the lift.
3.3.1 Installation requirements:
- The lift must be installed in accordance with the specified safe distances from walls, columns and other equipment (as shown in Fig. 4),
including the minimum distance 1000mm from walls. To prevent any emergencies and for the convenience of operation, a sufficient space
for exit passageway shall also be considered.
- On the installation site, power supply and air supply shall be provided and connected with the control cabinet station in advance, and the
ceiling height shall not be less than 4000mm. It is recommend to install the lift in a pit.
- Nevertheless, the lift can be installed on any indoor floor, provided that the floor meets the leveling requirements and has enough bearing
capacity (25MPa). During installation, there shall be sufficient light to ensure the safe operation of commissioning and repair. Strong light
shall be avoided, because it would affect personnel sight and cause eyestrain.
- The arrived goods shall be inspected for completeness before installation of scissor lift.
- The movement and installation of the lift shall be carried out by the professionals.
- For the transportation and storage of the machine, refer to the "Transportation and Storage" in page 10.