Valve torch SR/ABITIG
7.1 Sharpening the tungsten electrode
Sharpening the tungsten electrode depends on wear and must therefore be carried out when
required.
Sharpening the tungsten electrode
Fig. 2
DANGER
Health hazards caused by radioactive substances
Radioactive substances are released during welding and sharpening of tungsten electrodes
containing thorium.
• Use a suitable extractor unit.
To sharpen the tungsten electrode, use a sharpening device with a diamond disc.
• The point is sharpened longitudinally through the center axis.
• Automatic regulation of the tungsten electrode drive by gravity.
• Can be set for all electrode diameters.
• Offers continuous adjustment of the angle.

7.2 Basic cleaning

We recommend basic cleaning once a week. The type and frequency of cleaning shall be
determined and established by the system operator of the welding system.
8 Disposal
NOTICE
• Do not dispose of the device with household waste.
• For disposal, observe the local regulations, laws, provisions, standards and guidelines.