5.4 Start and stop of the
machine (when connected
to a water supply)
5.5 Start the machine (when
connected to open contai-
ners (suction mode))
5.6 Pressure regulation on the
®
TORNADO

PR- nozzle

Original Instructions
Note: Check that the fi lter is
fi tted in the water inlet pipe and
that it is not clogged up.
2. Connect the water hose to the
water supply by means of the
quick connector (inlet water,
max. pressure: 10 bar, max. tem-
perature: 40°C).
3. Turn on the water.
The spray lance is affected by a
thrust during operation - there-
fore always hold it fi rmly with both
hands. IMPORTANT: Point the
nozzle at the ground.
1. Check that the machine is in
upright position.
NOTE: Do not place the machine
in high grass!
2. Release the trigger lock.
3. Activate the trigger of the spray
gun and let the water run until all
air has escaped from the water
hose.
4. Turn the start/stop switch (1) to
position"I".
5. Activate the trigger of the spray
gun.
Always adjust the distance and
thus the pressure of the nozzle to
the surface, which is to be cleaned.
Do not cover the machine during
operation.
The washer can take in water from
a rain water tank as an example.
The hose for the water supply
must not be too long, approx. 5 m.
Make sure that the water tank is
not placed on a lower level than
the machine.
1. Place the other end of the water
High pressure
Højtryk
Lavtryk
Low pressure
Note: If the machine
is left or not used for
5 minutes, it must
be switched off on the start/stop
switch "O" (1):
1. Turn the start/stop switch (1) to
position"O".
2. Disconnect the electrical plug
from the socket.
3. Shut off the water supply and
activate the trigger to relieve the
machine of pressure.
4. Lock the spray gun.
When releasing the trigger of the
spray gun, the machine automati-
cally stops. The machine will start
again when you re-activate the
spray gun.
hose in the water tank. Use an
external fi lter if the water con-
tains impurities.
2. Turn the start/stop switch (1) to
position"I".
3. Activate the trigger of the spray
gun and let the water run, until
the air has escaped from the
water hose and the pump.
4. Mount spray lance and nozzle.
The pressure can be regulated on
®
the TORNADO
PR nozzle.