12. General settings

12. General settings
This chapter leads you through the parameters, step by step. Therefore, the
sub-chapters should be worked through in sequence. Dashed lines in the
diagrams indicate parameters that are skipped.
→ Complete menu tree from page 52

12.1 Setting the measuring time

The measuring time defines in which cycle the measured value is recorded. Via
this function the display of the measured value can be settled.
[☼]
TYPE
[▲] [▼]
SEC
Parameter
SEC

12.2 Setting the moving average determination

The display shows the moving average of the last 2 ... 20 measured values. There
is no weighting of the measured values.
[☼]
TYPE
[▲] [▼]
GLM
Parameter
GLM
WIKA operating instructions digital indicator, model DI32-1
00.1 ... 2.00
[☼]
Description
0.01 ... 2.00 seconds
0.00 ... 2.00 seconds (with pulse measurement)
1 ... 20
[☼]
Description
1 ... 20 (1 = moving average determination is deactivated)