7. Description of program numbers

7.1.3 Number of decimal places

Specifies the number of decimal places that are displayed on the screen. This param-
eter has no influence on the scaling of the indication value.
PN
Function
3
Number of decimal places, measuring input 1
8
Number of decimal places, measuring input 2

7.1.4 Offset adjustment

The input signal is shifted in parallel by the offset value.
PN
Function
4
Offset value, measuring input 1
9
Offset value, measuring input 2
This parameter can be altered directly by making a tare if this was
triggered through the multi-function button or the digital input.

7.2 General settings

7.2.1 Default display

Defines the measuring input which should be displayed as standard.
PN
Function
10
Default display
→ For arithmetic function see chapter 7.3 "Arithmetic function".
WIKA operating instructions digital indicator, model DI35-D
Parameter
00000 ... 0.0000
00000 ... 0.0000
Parameter
-9999 ... 99999
-9999 ... 99999
Parameter
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
EN