Fault
The interior light
is not functioning.
Floor of the
refrigerator com
partment is wet.
The temperature
in the cool fresh"
compartment is
too cold or too
warm.
Possible cause
Light switch is sticking. Fig. 1/3
The bulb, Fig. t/A or t/B,
is defective.
The condensation outlet is blocked.
Stopper is missing from the
condensation drainage hole.
The fixed setting has been set too
high or too low (e.g. if there is frost
in the "cool fresh" compartment).
Remedial action
Check whether it can be moved.
Change the bulb. Fig t/A
1. Pull out the mains plug or disconnect
the fuse.
2. Change the bulb
(replacement bulb, 220-240 V a.c.,
E14 bulb holder, see defective bulb
for wattage).
Change the bulb. Fig t/B
1. Pull out the mains plug or disconnect
the fuse.
2. Take out bottom glass drawer.
3. Change the bulb
(replacement lamp Osram "Dulux S",
7 W, G23 base).
Clean the condensation channel and
the outlet see Cleaning the appliance.
Fig. r
Insert stopper.
The temperature in the cool fresh"
compartment can be corrected.
Fig. 2
Press the buttons, 1 and 8, "-" at the
same time for two seconds until the
display 3 is highlighted. Keep pressing
button 8 until the required temperature
is displayed (consecutively from 1-4).
After twenty seconds the set temperature
is stored.
en
39