3.1.7 Power Supply Requirements
Make sure that the supply voltages and
WARNING
frequencies are suited to the characteristics
of the electric motor. Check the motor rating plate.
In general, the supply voltage tolerances for motor operation are
as follows:
f [Hz]
~
UN [V]
50
1
220-240
50
3
230/400
50
3
400/690
3.1.8 Sound Emission Level
See Fig.I , where P2 is the nominal rated motor power.
3.1.9 Special Applications
Please contact the Sales and Service
WARNING
Department in the following cases:
- if liquids with a density and/or viscosity value exceeding that o f
water (such as water and glycol mixture) must be pumped; as it
may be necessary to install a more powerful motor
-
if
chemically
treated
demineralized, ...) must be pumped
- if the pump must be installed horizontally (
and for any situation other than the ones described, related to
the nature of the liquid.
3.1.10 Improper Use
If the pump/electric pump unit is used improperly,
dangerous conditions may be created and personal
injury and damage to property may be caused.
Here are a few examples of improper use:
- pumping liquids that are not compatible with the pump
construction materials
- pumping hazardous (toxic, explosive, corrosive) liquids
- pumping liquids for drinking (wine, milk,......)
- installing the pump/ electric pump unit in hazardous
locations (explosive atmospheres)
- installing the electric pump unit in a location where the
air temperature is very high and/or there is poor
ventilation
- installing the electric pump unit outdoors where it is not
protected against rain and/or freezing temperatures
An improper use of the electric pump unit /pump leads to the
loss of the Warranty.
3.2 Warranty
Please refer to the sale contract for any information.
3.3 For UK market only (Installation Requirements and
Notes)
A WRAS label on the product means it is a Water Regulations
Advisory Scheme - Approved Product. This product is suitable
to be used with cold potable water for human consumption.
For further information, please refer to IRNs R001 and R420 in
the
WRAS
Water
Fittings
(www.wras.co.uk).
4. Transportation and Storage
4.1 Transportation, Storing and Handling of the Packed
Product
The pumps/electric pump units are packed in cartons or wooden
crates having different dimensions and shapes. Check the
outside of the package for evident signs of damage.
Some cartons (the supporting base is made
WARNING
of wood) are designed to be transported and
handled in the vertical position. Other cartons, as well as the
wooden crates, are designed to be transported and handled in
the horizontal position. Protect the product against humidity,
18
±%
f [Hz]
~
UN [V]
6
60
1
220-240
10
60
3
220/380
10
60
3
380/660
water
(softened,
section 9)
and
Materials
information for carriers
heat sources and mechanical damage (collisions, falls, ...). Do
not place heavy weights on the cartons.
Lift and handle the product care fully, using suitable lifting
equipment.
regulations.
The packed product must be stored at the following room
temperature range: -5° C to +40° C.
±%
4.2 Unpacking the Product
6
Use suitable equi pment. Observe all the accident
5
prevention regulations in force. Lift and handle the
10
product carefully, using suitable lifting equipment.
When the pump/electric pump unit is unpacked, check the
outside of the package for evident signs of damage that may
have occurred during transportation and storage.
4.2.1 Carton (for transportation in vertical position)
Remove the staples and open the carton. The pump/electric
pump unit is secured to the wooden base by screws.
4.2.2 Carton (for transportation in horizontal position)
deionized,
Remove the staples and open the carton. The pump/electric
pump unit is secured to one of the sides by screws or straps.
4.2.3 Wooden Crate (for transportation in horizontal
position)
Open the cover, pay attention to the nails and straps. The
pump/electric pump unit is secured to one of the sides by bolts
or straps.
4.2.4 Disposal of Packing Materials
If the packing container cannot be utilized for other purposes,
dispose of it according to the sorted waste disposal regulations
locally in force.
4.3 Handling the Product
Lift and handle the product carefully, using suitable lifting
equipment. Observe the accident prevention regulations
in force. Check the gross weight indicated on the
package to select proper lifting equipment.
The product must be securely harnessed for lifting and handling
Fig.F.
To move the electric pump unit:
•Use straps surrounding the motor if the electric pump
unit is equipped with the following motor power:
0.25÷4kW.
•Use ropes linked to the 2 flanges (or the 2 eyebolts, if
provided) located near the mating zone between
motor and pump with the following motor power:
5.5÷55KW
•Use eyebolts screwed onto the motor exclusively for
handling the individual motor and not for handling the
whole electric pump unit.
5. Installation
Directory
The installation operations must be carried out by
qualified and experienced personnel. Use suitable
equipment and protections. Observe the accident
prevention regulations in force.
Carefully read the installation limits specified in section 3.1.6.
Always refer to the local and/or national regulations, legislation
and codes in force relating to the selection of the installation site
and the water and power connections.
5.1.1 Position
Make sure that no obstructions or obstacles hinder the normal
flow of the cooling air delivered by the motor fan. Make sure
there is adequate clearance around the pump for the
maintenance operations. Whenever possible, raise the pump
Observe
all
the
accident
information for installers
information for installers
prevention