PROGRAMMING PARAMETERS
Meaning
Loop 2 input function
Light output function
Consult "Table 7" for information
on the single parameters
Flash output function
Consult "Table 7" for information
on the single parameters
OGI output function
Consult "Table 7" for information
on the single parameters
Level I
Level II
Effect after pressing the encoder (A)
parameters
parameters
Opens, with open-open sequence (normally open – NA – input)
1
Closes, with close-close sequence (normally open – NA – input)
L O 2
2
Photo (normally closed – NC – input)
4
24 V warning light
0
OGI
1
Boom closed
2
Boom open
3
Boom light warning light
4
Maintenance indicator
5
Courtesy light
6
O U 1
Red traffic light
8
Green traffic light
9
Radio channel no. 1
1 0
Radio channel no. 2
1 1
Radio channel no. 3
1 2
Radio channel no. 4
1 3
Suction cup
1 4
24 V warning light
0
12 V warning light
1
OGI
2
Boom closed
3
Boom open
4
Boom light warning light
5
Maintenance indicator
6
Courtesy light
O U 2
7
Red traffic light
9
Green traffic light
1 0
Radio channel no. 1
1 1
Radio channel no. 2
1 2
Radio channel no. 3
1 3
Radio channel no. 4
1 4
Suction cup
1 5
24 V warning light
0
OGI
1
Boom closed
2
Boom open
3
Boom light warning light
4
Maintenance indicator
5
Courtesy light
6
O U 3
Red traffic light
8
Green traffic light
9
Radio channel no. 1
1 0
Radio channel no. 2
1 1
Radio channel no. 3
1 2
Radio channel no. 4
1 3
Suction cup
1 4
ENGLISH – 75