1) Don't remove wire connected between contact "N"
of PCB and contact "3" of terminal block on cover
2) Don't remove wire connected between contact "L"
of PCB and contact "4" of terminal block on cover
1
2 POLES SWITCH (DPST)
2
POTENTIOMETER
( FROM 5 KOHM TO 10 KOHM)
3
ON/OFF SWITCH (SPST)
DRY CONTACT FOR
4
ALARM SIGNALLING
(250VAC, max current 3A)
18

WIRING TO AN EXTERNAL LOW/HIGH SPEED SWITCH

NOTES
1) Don't remove wire connected between contact "N"
of PCB and contact "3" of terminal block on cover
2) Don't remove wire connected between contact "L"
of PCB and contact "4" of terminal block on cover
1
2 POLES SWITCH (DPST)
2
LOW/HIGH SPEED SWITCH
SPST
DRY CONTACT FOR
3
ALARM SIGNALLING
(250VAC, max current 3A)
LINEO 315 V0 ES

WIRING TO AN EXTERNAL POTENTIOMETER

P0
P10
S1
S2
R1
R2
LINEO 315 V0 ES
P0
PI
P10
S1
S2
R1
R2
PCB Control Port Description
---------------------------------------
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm
PCB
N
L
PI
4
PCB Control Port Description
---------------------------------------
P0 = Potentiometer 0V = GND
PI = Potentiometer Input Signal = 0-10V
P10 = Potentiometer 10V = +10V
S1-S2 = dry contact for MAX/MIN speed
R1-R2 = dry contact for optional Alarm
PCB
N
L
MAX
MIN
2
3
2
COVER
3
COVER
4
3
L2
N1
1
N
L
4
3
L2
N1
1
N
L