• Appliances of class II:
with SELV circuits .
• Number of manual cycles: 3,000 .
• Number of automatic cycles: 100,000 .
• Type of contact opening: micro-disconnection .
• Type of action: 1 BU .
• Tracking index: PTI175 .
• Pollution rating: 2 (normal) .
• Nominal pulse voltage: 4,000 V .
• Ambient temperature during transport: -25 °C +60 °C .
• Operating temperature: T40 (0 °C +40 °C) .
• ErP classification (Reg . EU 811/2013): class I, contribution 1%
• Software class: A .
11. INSTALLATION RULES.
• Installation should be carried out observing current installation
regulations for electrical systems in the country where the products
are installed .
12. CONFORMITY TO STANDARDS.
LV Directive .
EMC Directive .
Standards EN 60730-1, EN 60730-2-9 .
ENGLISH - 35