Gallagher 3E3446 M5800i/M10000i Energizer User Manual
Current Alarm
The factory default setting is current alarm disabled (shown by --). To improve
your ability to find faults before your fence becomes ineffective (voltage too low),
Gallagher recommend setting the current alarm 10A above normal operation.
Many events can cause the current to increase, including rainfall, grass growth,
broken fences and failed insulators. If the current goes above the alarm level you
have set, then the Energizer icon (
Status LED
flashes red
Adjusting / Turning Off Alarms
a)
Press the setup button (
b)
Press the navigation buttons (< or >) to move the zone indication arrow (
over the desired zone, which will flash when selected.
c)
Press (- or +) to adjust the zone alarm level.
d)
To disable an alarm press (-) until the display shows (- -).
e)
To exit, press the setup button (
Controller showing the energizer in current alarm
).
Controller showing the default energizer alarm setup with
current disabled and voltage at 3.0KV
) will flash and the status LED will flash red.
) or wait 10 seconds.
)
13