Chapter 7
7.1 - DISMANTLING THE MACHINE
Proceed by complying with the instructions given in
the "Installation" chapter, working in reverse order, if
the machine must be dismantled and then moved to
another site.
DANGER
Before disassembling the machine or demounting
some machine components, disconnect the power
supply.
The machine assembling shall only be carried out
by skilled and authorized personnel.
ATTENTION
In case it is necessary to disassemble the machine
or demount some machine components in a dif-
ferent way in comparison with the written instruc-
tions, Company manufacturer or its Agent shall be
contacted - see addresses on the third page of this
publication.
7.2 - DEMOLISHING THE MACHINE
To protect the environment, please
proceed in compliance with the local
laws in force.
When the machine can no longer be
used or repaired, please proceed with
recycle and disposal.
Electrical equipment cannot be disposed of as ordi-
nary urban waste: it must be disposed of according
to the special EU directive for the recycling of electric
and electronic equipment (leg. decree no. 49 dated
14/03/2014 implementing the directive 2012/19/EU
RAEE and leg. decree no. 27 dated 4/03/2014 im-
plementing directive 2011/65/EU ROHS).
Electrical equipment is marked with a pictogram of
a garbage can inside a barred circle. This symbol
means that the equipment was sold on the market
after August 13, 2005, and must be disposed of
accordingly.
Due to the substances and materials it contains,
inappropriate or illegal disposal of this equipment, or
improper use of the same, can be harmful to humans
and the environment. Improper disposal of electric
equipment that fails to respect the laws in force will
be subject to administrative fines and penal sanctions.
EN - 24
Dismantling - Demolition - Disposal
ATTENTION
Consult the next paragraph when disposing of
harmful materials (lubricants, solvents, coating
products, etc.).
7.3 - DISPOSING OF HARMFUL SUBSTANCES
Consult the provisions established by the Standards
in force in each individual country before disposing of
such substances.
ATTENTION
Any improper use by the Customer before, during
or after scrapping and disposing of the parts of
the machine, in respect of the construction and
application of the applicable regulations, shall be
the customerʼs responsibility.
ELECTRIC PANEL CODES
KM1:
Up contactor
KM2:
Down contactor
KM3:
Lower plate resistance relay
M:
Three-phase electric motor
R1:
Lower plate resistance
R2:
Upper plate resistance
SQ1:
Phase inversion block microswitch
SQ2:
Upper microswitch
SQ3:
Lower microswitch
SQ4:
Cover position microswitch
SQ5:
Cover position microswitch
SB1:
Operating button
SB2:
Operating button
KT1:
Timer 0 - 6 sec.
FR1:
Thermal inside the motor
X2:
15 pole connector male / female
M1:
Three-phase motor 0,25 Kw 230/400 V
ST1:
Upper resistance thermostat
ST2:
Lower resistance thermostat
ST3:
Safety thermostat
HL2:
Upper resistance thermostat
HL3:
Lower resistance thermostat
PF 33 MT - PF 46 MT