Herunterladen Inhalt Inhalt Diese Seite drucken

Control Of A Correct Electrical; Connection; Unipotential Connection; First Start - OEM PRESSFORM PF 33 MT Gebrauchs- Und Instandhaltungshandbuch

Pizza-formmaschinen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 85
PF 33 MT - PF 46 MT
Installation and connections
3.3.a - CONTROL OF A CORRECT ELECTRICAL
CONNECTION (FIG. 4)
For the connection 400 V three phase, it is necessary to
check if the engine rotation is right, to do this proceed
as follows:
Turn the cut-out switch placed on the upper machine
side to "ON".
Press the main switch (1) "Position I", it lights up.
If the connection is correct, the upper dish (2) will rise.
If the connection is incorrect, the dish (2) will lower,
therefore, immediately turn off the machine by set-
tingthe switch (1) to "0" and turn offthe switch located
upstream of the machine
DANGER
Before making any change in the electrical connec-
tion, make sure that the DISCONNECTING SWITCH
is disconnected (line not energized), then: two of
the three phases on the cutout switch shall be inverter-
ted, then, make sure the functioning is correct.
3.3.b - UNIPOTENTIAL CONNECTION (Fig. 4)
The machine is provided with a screw (3) for unipotential

connection.

To make the connection, unscrew the screw nut (3),
connect the cable of the unipotential net to the screw
and tighten the nut again.
3.4 - FIRST START (Fig. 4)
Start the machine as indicated in the paragraph "Ma-
chine Functioning" and make sure all units properly
function.
FIG. 4
2
S
3
4
2
120
5
1
140
100
6
160
0,1
80
0
180
60
1
3
120
100
140
160
80
180
60
EN - 11