Herunterladen Inhalt Inhalt Diese Seite drucken

Models With Thermostat Mixer Tap - Jacuzzi Designer Collection Serie Bedienung Und Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 52
MODELS WITH SINGLE-CONTROL MIXER TAP
It is advisable to set the water temperature to the required
value before using any function with the tub filling jet:
I Turn the diverter valve dial (3) to the "tub filling" position (A).
I Pull the mixer lever (1) to open the water flow and turn it to
adjust the temperature.
The maximum temperature of the mixed water must not be
hotter than 60° C.C.
I When the water is at the required temperature, turn the dial (3)
to the required function.
NOTES
I
Two functions may be used at the same time: simply turn the
diverter valve dial the mid-way between the two functions. For
example, to use all nozzles at the same time, position the dial
between the symbols (E1) and (E2); obviously, the water pressure will
drop and consequently so will the power of each jet.
Remember to close the mixer after each use.
A
B
C
E1
E2

MODELS WITH THERMOSTAT MIXER TAP

i
I (
14) In these models, it is easier to adjust the water
temperature because the temperature is shown in degrees
centigrade (°C) directly on the thermostat mixer dial.
It is advisable to set the water temperature to the required value
before using any function with the hand shower or the tub filling
jet. Proceed as follows:
I Turn the knob (1) to make the reference notch coincide with
the chosen value. The knob is provided with a safety stop which
blocks the temperature at 38°C; press button (1a) to release the
knob to select hotter temperatures.
The maximum temperature of the mixed water must not be
hotter than 60° C.
I To test the water temperature, turn the diverter valve dial (3) to
the "tub filling" position (A) and turn the stop tap (2) to make
water flow.
I Once the required water temperature is reached, turn the
diverter valve dial (3) to the position of the required function.
NOTES
I
Two functions may be used at the same time: simply turn the dial
of the diverter valve mid-way between the two functions. For
example, to use all nozzles at the same time, position the ring
between the symbols (E1) and (E2); obviously, the water pressure will
drop and consequently so will the power of each jet.
Remember to close the stop tap (2) after each use. If
3
temperatures higher than 38 °C are selected, it is advisable to
turn the dial of the thermostat mixer back before the safety
stop.
2
1a
1
3
2
1a
1
14
26

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis