For ULISSE units fitted with ZFI cameras, set the Int.
value under IR Probe, in the ZFI Camera Settings
menu ("9.6.3 ZFI camera settings menu", page 34).
ZFI CAMERA SETTINGS
------------------------
1>ZOOM
3 IR PROBE
4 ZONE TITLING
5 ZONE MASKING
Fig. 32
7.1.6.5 Infrared illuminator on from
keyboard
To switch on the infrared illuminator from the
keyboard:
• Adjustment of the illuminator on the left
(MASTER):
• Lighting threshold: Set the value to the
minimum ("7.1.6.6 Adjusting the illuminator trip
threshold", page 21).
• Infrared power: Set the value as needed
("7.1.6.7 Adjusting the illuminator power",
page 21).
20
:
30x
:
INT.
>
>
• Adjustment of the the illuminator on the right
(SLAVE):
• Lighting threshold: Set the value to the
maximum ("7.1.6.6 Adjusting the illuminator trip
threshold", page 21).
• Infrared power: Set the value to the minimum
("7.1.6.7 Adjusting the illuminator power",
page 21).
• Set the Off value under IR Probe in the Main
menu > Block camera > Advanced > Infrared
menu ("9.6.6.10 Advanced setting menu (Infrared)",
page 43).
INFRARED
------------------------
1>IR PROBE
Fig. 33
To operate the infrared illuminator, refer to "11.9
Enabling the Infrared illuminator", page 58.
:
OFF