Herunterladen Inhalt Inhalt Diese Seite drucken

EFOY Pro 800 Bedienungsanleitung Seite 34

Vorschau ausblenden Andere Handbücher für EFOY Pro 800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Data Port Commands
Command
DUOCARTSWITCH
[ON / OFF / SWITCH 1
/ SWITCH 2]
FUELGAUGE
[ON / OFF]
Output in the terminal program
NOTE!
Command DUOCARTSWITCH only for:
EFOY Pro 600 / 1200 / 1600 / 2200 / 2200 XT
For activation of DuoCartSwitch DCS1 with EFOY Pro 800 / 800 Duo /
2400 / 2400 Duo please refer to command "CARTRIDGE".
This function must be activated while using the DuoCartSwitch for the
first time. Remains active untill it will be deactivated. A fuel cartridge
change to another cartrigde can be set by a parameter:
SFC>DUOCARTSWITCH on
battery voltage 12.64 V
output current 0.00 A
operation time (charge mode) 166.1 h
operating state: auto off
operating mode: auto
cumulative output energy 14809.9 Wh
no error
cartridge level above sensor or no sensor (cartridge 1 consumed
0.00 l)
SFC>DUOCARTSWITCH SWITCH 2
Switches from fuel cartridge 1 to fuel cartridge 2
If the command is output without the parameter, the EFOY unit output
is "SFC". The last line „cartridge level above sensor or no sensor
(cartridge 1 consumed 0.00l)" shows, that the DuoCartSwitch is
activated.
NOTE!
Command FUELGAUGE only for:
EFOY Pro 800 / 800 Duo / 2400 / 2400 Duo
Allows you to deactivate/activate the fuel gauge, which is displayed on
the operating panel OP2.
SFC>FUELGAUGE OFF
OFF (deactivated)
SFC>FUELGAUGE ON
ON (activated)
31