Select a suitable location for the device taking into account all the
aforementioned warnings in this manual.
Only connect the heater to an earthed socket!
Permanent mounting:
The QH1203 is designed for installation in a permanent position and direct connec-
tion to the electricity network. For safety reasons, this installation should be fitted
by an approved electrician.
Plug connection:
The QH1203 can also be connected directly to a power socket using the electric ca-
ble and plug. Make sure that the electric cable does not hang over any (sharp) edg-
es, does not make any sharp angles, cannot be dragged and does not touch any
hot surfaces.
Important: the electric cable and plug form a whole. Therefore, if either the elec-
tric cable or plug is damaged they should both be replaced by an electrician. Only
mount the original parts!
When positioning and connecting the heater, make sure that your hands do not
touch the heating elements. This is because traces can be left behind which, af-
terwards, will have a negative effect on the radiated heat.
For use with a plug, the following applies: do not use extension leads and do not
connect any other equipment next to the heater in the same socket!
Position the mounting bracket with the long side and 2 holes against the wall in
the required position, then mark the drill holes. Make sure that the drill holes are
positioned at the same height! Remove the bracket and drill 2 holes in the spots
marked. Knock in the raw plugs, position the bracket over the top and screw it
firmly into the wall using the screws supplied.
Place the heater over the bracket with the cord down and large holes positioned
over large holes. Screw securely using the bolts, rings and nuts supplied (1).
Turn the heater to the required position. The body of the heater can be turned to
5 positions (Small heater holes over small bracket holes (3)). The mid position is
horizontal to the room. The two positions which
are directed upwards will only be used in ex-
ceptional cases and require a greater distance
to the ceiling (1 metre). Finally, the heater has
two positions which are directed downwards.
These are the standard positions. Secure the
heater at the required angle by screwing both
of the small screws (2) into the double holes.
The heater is now ready for use.
The QH1203 is supplied with a knob, ring and spring washer that is intended for a
special model. These parts are surplus and not intended for your model.
28