Herunterladen Inhalt Inhalt Diese Seite drucken

Display Indications - Erreka VIVO-M203 Kurzführer Installation Und Programmierung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

If the operator has a brake connected internally to the motor (e.g. ORION operators), the brakes do not need
to be connected, although slowdown should be cancelled (select CA00).
M203: 230V/50Hz
FR1
FR2
The display shows a horizontal segment in D4 whenever no
key is pressed for 15 minutes. This will light up when any
of the ESC, ENTER, UP, DOWN pushbuttons are pressed.
D1 and D2 (gate status):
CL
(static)
CL
(flashing)
OP
(static)
OP
(flashing)
PC
(flashing)
PO
(static)
PO
(flashing)
XX
(countdown)
PA
(static)
rS
(static)
FtP
(flashing)
StOP
rSC4
Opening photocell failure when connecting the
power supply
rSC5
Closing photocell failure when connecting the
power supply
rSC9
Safety strip failure when connecting the power
supply
12
COM
F1
L1
L2

Display indications

Gate closed
Gate closing
Gate open
Gate opening
Pedestrian gate closing
Pedestrian gate open
Pedestrian gate opening
Gate on standby
Pause (operation not complete)
Gate
resetting
(searching
opening or closing position)
Communicating with the server
Operator unlocked
Gate type selection (C3)
6
Select gate type:
C301: swing
C302: sliding
C303: up-and-over
N141E
Brake cabling
If the operator has a brake to connect
independently (for example, CICLON or MAGIC
operators), use the EPS1 card as shown in the
diagram and select the parameter Ab01.
EPS1
P241Z5
D3 and D4 (error messages):
C4
Opening safety device activated
C5
Closing safety device activated
C9
Mechanical or resistive strip activated
E1
Motor 1 encoder failure
E2
Motor 2 encoder failure
F1
Motor 1 force limit exceeded
for
F2
Motor 2 force limit exceeded
FtC4
Opening photocell test error (failure)
FtC5
Closing photocell test error (failure)
çotC
(flashing): no GSM coverage
çotP
(flashing): GSM pin fails
In swing gates, C4 refers to the interior photocell
and C5 refers to the exterior one (instead of
opening and closing, respectively).
DL1: Red LED, FR1 activation
DL2: Green LED, FR2 activation
N141C
N141G
N141D

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vivo-m203m

Inhaltsverzeichnis