Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Assembly instruction
Connector type: 11_SMA-50-1-53
EZ_47, SUCOFORM_47
Suitable cables:
Parts list connector:
Assembly steps:
Picture
EZ Kabel
SUCOFORM
10
B
A
C
X
W 52 body
C
±0.125
0.125
±0.125
0.125
The cable assembly of R.F. connectors can only be done by well trained assembly staff and suitable assembly equipment.
Huber+Suhner's skilled staff and specialised equipment are available to carry out complete R.F. lead-assembly on your behalf.
We mount your connectors on cables at economic prices! Please contact our representative for further details of this service.
Series SMA
C
B
A
Process
For EZ and SUCOFORM
The tool must be set for
2.5mm stripping
dimension.
2.5
2.5
Prepare cable according to
diagram.
Dimension 10mm applies
to SUCOFORM with
2
.
5
jacket.
Slide insulator A onto
cable.
Push contact B over inner
conductor completely
against insulator A and
solder.
Mount locator tool
W 14 onto body C.
Push prepared cable into
body C and solder at X.
Screw body of tool W 52
D
onto connector body C.
Place insulator D in rear
opening of insert tool.
Press insulator D fully
W 52
through insert tool using
plunger
the plunger.
Check interface
dimensions.
0000183975
Old Assembly instruction No. 150006
Inner conductor contact:
Outer conductor contact:
D
Feature / Check
Cut cable end
perpendicular to cable
axis.
Do not damage centre
contact, dielectric and
braid.
Avoid excessive heat.
Avoid excessive heat.
Promptly swap soldered
area with alcohol to cool
joint and remove any
residual flux.
Press in insulator until
stop.
Insulator :
0.125
±0.125
Centre contact :
0.125
±0.125
Deutscher Text: siehe Rückseite
Soldered
Soldered
Tools required
Stripping tool W 157.
See instruction sheet
DOC-0000199604 for
detailed description.
Stanley blade
Soldering iron
Solder
Locator tool W 14 (M)
Insert tool W 52
Revision
D
Date
22.02.2012
Initiator
4952 / WiS

Werbung

loading

Inhaltszusammenfassung für HUBER+SUHNER SMA Serie

  • Seite 1 0.125 The cable assembly of R.F. connectors can only be done by well trained assembly staff and suitable assembly equipment. Revision Huber+Suhner’s skilled staff and specialised equipment are available to carry out complete R.F. lead-assembly on your behalf. Date 22.02.2012 We mount your connectors on cables at economic prices! Please contact our representative for further details of this service.
  • Seite 2 0.125 Version Die Montage von HF-Verbindern kann nur durch geschultes Personal, das über die richtige Ausrüstung verfügt, erfolgen. Huber+Suhner verfügt über ausgebildete Fachkräfte und rationelle Einrichtungen zur Herstellung kompletter HF-Verbindungs- Datum 22.02.2012 leitungen. Wir montieren Ihre Verbinder zu wirtschaftlichen Preisen! Wenden Sie sich an unsere Vertreter.

Diese Anleitung auch für:

11 sma-50-1-53