Herunterladen Inhalt Inhalt Diese Seite drucken

Table 22: Default Settings Of Inputs; Table 23: Input Configuration - DAB ACTIVE DRIVER PLUS M/T 1.0 Installations- Und Wartungsanleitungen

Vorschau ausblenden Andere Handbücher für ACTIVE DRIVER PLUS M/T 1.0:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 149
Value
Function associated with general input i
0
Input functions disabled
1
Water failure from external float (NO)
2
Water failure from external float (NC)
3
Auxiliary setpoint Pi (NO) related to input used
4
Auxiliary setpoint Pi (NC) related to input used
General enable of the inverter from external signal
5
(NO)
General enable of the inverter from external signal
6
(NC)
General enable of the inverter from external signal
7
(NO) + Reset of resettable blocks
General enable of the inverter from external signal
8
(NC) + Reset of resettable blocks
9
Reset of resettable blocks NO
Low pressure signal input NO, automatic and
10
manual reset
Low pressure signal input NC, automatic and
11
manual reset
12
NO low pressure input, manual reset only
13
NC low pressure input, manual reset only
General enabling of the inverter by an
14*
external signal (NO) without error message
General enabling of the inverter by an
15*
external signal (NC) without error message
* Function available for firmware V 2.0.0 and later versions
6.6.15.1 Disabling functions associated with input
If an input is configured at 0, each function associated with this input will be disabled, regardless of the signal on the
terminals of the input itself.
6.6.15.2 Setting the external float function
The external float can be connected to any input, for all electrical connections, refer to paragraph 2.3.3.
The float function is obtained by setting the parameter Ix, for the input to which the float signal has been connected, on
one of the values in Table 24.
Activation of the external float function generates a system block. The function is envisaged to connect the input to a
signal from a float that indicates a water supply failure.
When this function is enabled, the symbol F1 is shown on the STATUS line of the main page.
The input must be activated for at least one second for the system to block and indicate the error F1.
When in the F1 error condition, the input must be deactivated for at least 30 seconds before the system unblocks.
The function behaviour is summarised in Table 24.
When several float functions are configured at the same time on different inputs, the system indicates F1 when at
least one function is activated and clears the alarm when none are activated.
ENGLISH
Default settings of inputs
IN1, IN2, IN3
Input
1
2
3
Table 23: Default settings of inputs
Summary of possible configurations of digital
inputs IN1, IN2, IN3 and relative operation
Table 24: Input configuration
Value
1 (float NO)
3 (P aux NO)
5 (enable NO)
Display of active function associated
88
with input
F1
F1
F2
F2
F3
F3
F3
F3
F4
F4
F4
F4
F3
F3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis