Herunterladen Inhalt Inhalt Diese Seite drucken

General Information; Safety Information; Use Of Hazard Information - Hach FL1500 Basis-Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
Specification
Analog input
Analog outputs
Relays
Digital inputs (advanced model
only)
Digital outputs (advanced
model only)
Certifications
Warranty
Expanded manual version
For additional information, refer to the expanded version of this manual, which is available on the
manufacturer's website.

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer's website.

Safety information

The manufacturer is not responsible for any damages due to misapplication or misuse of this product including,
without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent
permitted under applicable law. The user is solely responsible to identify critical application risks and install
appropriate mechanisms to protect processes during a possible equipment malfunction.
Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do so could result in serious injury to the
operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this
equipment in any manner other than that specified in this manual.

Use of hazard information

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious
injury.
Indicates a potentially hazardous situation that may result in minor or moderate injury.
4 English
Details
One 0/4–20 mA input (current input mode: 0/4–20 mA; 18 VDC maximum;
108 Ω and 0.4 V maximum loop burden).
Two (basic model) or three (advanced model) 0/4–20 mA outputs (0/4–20 mA
current loop; external loop power 18 VDC maximum or internal loop power
14 VDC minimum, 18 VDC maximum; loop burden 3.6 V maximum at 25 mA).
Two high voltage relays; Form C, SPDT, 20–230 VAC, 2.0 A
Two digital inputs; each digital input has a positive terminal and a shared
common with an input resistance of 120 kΩ and maximum input voltage of 30 V.
The default threshold is 1.5 V. When the optional user-supplied threshold is
used, the threshold is set at 50% of the voltage applied to the threshold pin (0 to
25 VDC)
Two digital outputs; low voltage contact closures mapped to alarm events
(±30 VDC or 20 VAC-rms at 0.15 A maximum); optional pull-up resistor to
externally-supplied logic level (0 to 30 VDC)
CE, cETLus, RCM
1 year (EU: 2 years)
N O T I C E
D A N G E R
W A R N I N G
C A U T I O N

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis