Draught vent (A)
Left position = closed.
Right position = fully open.
Doorhandle (B)
Towards the left = open. Towards the right = closed.
Doorhandle (C)
Towards the right = open. Towards the left = closed.
Ash door (E)
Open the door by turning the handle counter-clockwise one
half rotation. Use a glove or similar and pull out the tray.
Note! Only remove the ashes when the stove is cold
Mounting of flue pipe
It is advisable to carry out a test assembly prior to making
a hole in the chimney. See fig. 2 for measures to wall made
of flammable materials. The stove is installed with a 150
mm diameter flue pipe. This must be an approved thickness.
The flue outlet for Jøtul F 600 is inside the burn chamber
during transportation. You can choose between a top or
rear outlet from the flue pipe. The screws for fastening
are in the bag containing screws.
• Flue pipes 150 mm dia. are placed directly onto the
product flue outlet. There is a screw on both sides of
the product flue outlet (fig. 4-A). These are used to
fasten the flue pipe.
• Mark where the screws hit the flue pipe when it is at
the very bottom of the flue outlet and drill a 5,5 mm
hole for the screw in the flue pipe.
• Use gasket and cement to seal between flue pipe and
product flue outlet. Place the gasket around the lower
part of the flue pipe and fill up the space with cement.
• Fasten the flue pipe with screws.
Note! It is important that the joints are completely sealed.
Air leakage etc. may lead to malfunction.

Connection to chimney

Drill a hole for the flue pipe. Distance from stove to firewall/
chimney should be as shown in fig. 2. Always use a chimney
collar when connecting to chimney. Use the supplier's
recommended chimney collar when connecting to an
element chimney. Follow the supplier's assembly and usage
instructions closely with regard to mortar/furnace cement
before starting to use the fireplace.
Ensure that the flue pipe never slopes down towards the
chimney. It should at least be horizontal, preferably have
an incline of a few millimeters.
Note! A correct and sealed connection is very important
for the proper functioning of the product.
Be alert to the fact that it is particularly important that
connections have a certain flexibility. This is to prevent
setting of the house from leading to fissuration.
Operating instructions
Initial lighting and daily use
Jøtul F 600 is a clean-burning product and with additional
supplies of combustion air, it allows for afterburning of
hazardous gases and particles. It is important that the
system is used correctly.
The stove is equipped with certain functions that are
described in the chapter: Control of functions.

Initial lighting

Open the draught vent fully by pushing the vent all the way
to the right (fig. 3-A). Put in some crumpled newspaper,
kindling wood and firewood and start a small fire. Add more
firewood gradually and let the fire burn briskly for a couple
of hours. Let the fire die out and repeat one more time.
Note! Odors when using the stove for the first time.
Painted products. The stove may emit an irritating gas when
used for the first time, and it may smell a little. The gas is
not toxic, but it is recommended to open a window or a
door to provide additional ventilation in the room. Let the
fire burn with a high draught until all traces of gas have
disappeared and no smoke or smells can be detected.
Enamelled products: Condensation may form on the surface
of the stove the first few times it is used. This must be
wiped off to prevent permanent stains forming when the
surface heats up.

Daily use

Fire up with the aid of newspapers and some kindling wood.
Place two medium sized logs in/out on each side of the
base. Crumple some newspaper (or birch bark) between
these and add some kindling wood in a criss-cross pattern
on top and light the newspaper. Increase the size of the
logs gradually.
Draught vent (fig. 3-A). Regulate when the wood is properly
lit and burns well. Check that the afterburning (secondary
combustion) starts. This is best indicated by yellow, flickering
flames in the air chamber. Then regulate the rate of
combustion to the desired level of heating by adjusting the
draught vent.
Always use good quality firewood. It gives the best results
and does not damage the product.
Never burn the following materials in the stove:
-
household waste, plastic bags etc.
-
painted or impregnated wood (highly toxic)
-
chipboard or laminated boards
-
driftwood
This may harm the product and pollute the atmosphere.