Herunterladen Inhalt Inhalt Diese Seite drucken

Connect The Hydraulic Hose(S) - Holmatro HTW 300 ABU Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 51
5.1.3
Dual-hose couplers
The dual-hose couplers are used on single or dual hoses. In case of dual hoses, the supply hose and
the return hose are bundled together with ties. Each end of the hose(s) has a female and a male
coupler. If you want to connect or disconnect a tool and/or a hose, you must first set the pressure relief
valve handle on the pump to the pressure relief position. After connecting the hose(s) and the tool you
must set the pressure relief valve handle to the operation position so you can use the tool.
5.1.4
Pressure relief valve handle (if applicable)
The pressure relief valve handle is on the body together with the hydraulic couplers.
The pressure relief valve handle must be in the neutral position when you connect and disconnect
the hydraulic hoses.
The pressure relief valve handle must be in the operation position, when you use the equipment.
5.2

Connect the hydraulic hose(s)

5.2.1
General
WARNING
Never use damaged couplers.
CAUTION
Never use pliers or similar to connect the hydraulic couplers.
5.2.2
Hoses with CORE™ couplers
Refer to Fig. 6.
Remove the dust caps from the couplers.
Check the couplers for dirt and damage and clean them if necessary.
Insert the couplers by holding them against each other and pushing the male coupler with one
action into the female coupler. The external ring of the female coupler must move in the opposite
direction to the arrows.
Pull both couplers to check whether the couplers cannot be pulled apart with a normal manual
effort.
Put the dust caps into each other to avoid dirt.
5.2.3
Hoses with dual-hose couplers
Refer to Fig. 7.
WARNING
Always make sure that the pressure relief valve is in the open (0) position, before you
connect hydraulic hose(s) to the pump.
Remove the dust caps from the couplers.
Check the couplers for dirt and damage and clean them if necessary.
Push the couplers into each other. The external ring of the female coupler will automatically move in
the opposite direction to the arrows and lock.
Check whether the couplers can not be pulled apart with a normal manual effort and check that the
snap ring is in the correct position.
Put the dust caps into each other to avoid dirt.
HTW/FTW/HTT
916.000.192_003
EN
27

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis