SYSTEM SET UP
When you start a charge process, the integral
safety time automatically starts running at the
same time. This is programmed to prevent
overcharge the battery if it proves to be faulty,
or if the termination circuit cannot detect the
battery full. The value for the safety time should
be generous enough to allow a full charge of the
battery.
Safe time Calculation
When charging NiMH or NiCD batteries, divide
the capacity by current, then divide the result by
11.9, set this number as the value for safety time
setting. If the charger stopped at this threshold,
about 140% of the capacity will have been fed
into the battery.
For example:
This program sets the maximum charge
capacity that will be supplied to the battery
during charge. If the deltapack voltage is not
detected nor the safety time expired by any
reason, this feature will automatically stop the
process at the selected capacity value.
The battery's internal chemical reaction will
cause the temperature of the battery to rise. If
the temperature limit is reached, the process will
be terminated.
You can choose the temperature displayed by
Celsius or Fahrenheit as you like.