LITHIUM BATTERY CONNECTION DIAGRAM
Temperature Threshold*
The battery's internal chemical reaction will cause the temperature of
the battery to rise. If the temperature limit is reached, the process will
be terminated.
*This function is available by connecting optional temperature probe,
which is not included in the package.
Processing Time Limit:
You can also limit the maximum process time to avoid any possible
defect.
The MODSTER Charger 60 comes with the built in switch mode power
supplies.
You can connect the AC power cord directly to the main AC socket
(100-240V AC).
PLEASE NOTE:
The charger MUST be powered before you connect a battery to the
charger, failure to have the charger powered up before connecting a
battery can cause charger failure if any connections are incorrect. The
charger must to be powered in order for it to recognize an incorrect
connection and warn you of this before you can go too far and cause
damage. If you get the warning "Reverse Polarity" you MUST
disconnect the battery immediately! Never remove power from the
charger first.
Before connecting any battery it is absolutely essential to check one
last time that you have set the charging parameters correctly. If the
settings are incorrect, the battery may be damaged, and could even
burst into flames or explode. Check that your wiring is correct polarity
from the charger to your battery, double check to be safe.