Herunterladen Inhalt Inhalt Diese Seite drucken

Step 6: Close The Housing - Abus FUBW50120 Installations- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation
Walk test
• Set the alarm system to walk test mode (see corresponding user guide).
• Leave the area monitored by the detector and wait for the rest period after each test (see
"Rest period").
• Carry out several walk tests to test the surveillance partition.
• If the detector is triggered when it is not meant to be triggered, please check the installation
location of the detector again (see "Position").
A 30-minute walk test period is integrated in the detector. It begins when the batteries
are inserted or when the tamper contact is opened.
Note
The LEDs are activated during this period and the 3-minute rest period is deactivated.
The detector can be triggered again during this period approx. 7 seconds after
completion of the last HF transmission.

Step 6: Close the housing

• Close the cover and fully tighten the cover fixing screws.
54 |
E N

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis