Herunterladen Inhalt Inhalt Diese Seite drucken

mundoclima MUPIR-H9 Installations- Und Benutzerhandbuch Seite 49

Vorschau ausblenden Andere Handbücher für MUPIR-H9:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

6.3.3.1 Parameter Query interface " PQ"
The digital tubes near inlet water icon will display the item code. The digital tubes near outlet water
icon will display the item value.
Item code
1
2
3
4
5
6
7
8
9
10
11 - 15
16
17
18 - 20
21
22
23
24
25
26
6.3.3.2 History Fault interface " HF"
The digital tubes near inlet water icon will display latest 5 series number of error and protection codes.
The digital tubes near outlet water icon will display the error or protection code according to each series
number of the codes. E or P will be displayed after the point in the screen right side.
Item value
Running frequency of compressor (Hz)
EEV Open degree (Displayed value/5)
Ambient air temperature (ºC)
Outlet water temperature (ºC)
Discharge temperature of refrigerant (ºC)
Suction temperature of refrigerant (ºC)
Air side heat-exchanger pipe temperature (ºC)
Outlet refrigerant temperature of EXV (ºC)
Water pump status (0=Off, 1=On)
4-way valve status (0=Off, 1=On)
Reserved
Current of compressor (Displayed value /10)
Voltage (Displayed value ×10)
Reserved
Fan speed (Displayed value ×15)
DC link voltage (Displayed value ×5)
DC link current (Displayed rounded the current)
PFC temperature (ºC)
IPM temperature (ºC)
Frequency target of compressor
49