EN
W-77 | W-71 Spray Guns _ PRESSURE | SUCTION | GRAVITY
ANEST IWATA spray gun, has been designed for the application of
paints, lacquers and other products that can be atomized by means
of compressed air, on all surfaces suitable to receive this type of
treatment.
Before use, adjustment or maintenance, it is important to read
this instruction manual very carefully. This manual must be
stored in a safe place for any future reference.
This ANEST IWATA spray guns kit complies to ATEX
regulations ATEX 2014/34/EU.
Protection level: II 2 G X Suitable for using Zones 1 and 2.
X marking: Any static electricity discharged from the spray gun is to be diver-
ted to the ground via the conductive air hose as stipulated.
ALWAYS observe WARNINGS and CAUTIONS in this
instruction manual.
Symbol
WARNING
Hazard level
WARNING
POTENTIALLY
CAUTION
HAZARDOUS
IMPORTANT
1. TECHNICAL SPECIFICATIONS
Models
Max. working air pressure:
Weight g (lbs):
Noise level (LAeqT)*:
Air Connection:
Fluid Connection:
Max. Temperature range:
* Measuring point: 1m backwards from gun, 1.6 m height.
1.1 TECHNICAL DATA
MODELS
W-77 0
PRESSURE
1.2
W-77 1S
1.5
W-77 2S
SUCTION
2.0
W-77 3S
2.5
W-77 1G
1.5
W-77 2G
GRAVITY
2.0
W-77 3G
2.5
W-71 0
PRESSURE
0.8
W-71 1S
1.0
W-71 2S
1.3
W-71 3S
1.5
SUCTION
W-71 4S
1.8
W-71 21S
1.3
W-71 31S
1.5
W-71 1G
1.0
W-71 2G
1.3
W-71 3G
1.5
GRAVITY
W-71 4G
1.8
W-71 21G
1.3
W-71 31G
1.5
2. SAFETY WARNING
FIRE AND EXPLOSION
Never use the following HALOGENATED HYDROCARBON SOLVENTS:
which can cause cracks or dissolution of gun body (aluminium) due to chemical
reaction. UNSUITABLE SOLVENTS: methyl chloride, dichloromethane, 1.2-dichlo-
roethane, carbon tetrachloride, trichloroethylene, 1.1.1-trichloroethane
2
Consequence
Death or serious injury
Minor to moderate injury
SITUATION
Property damage
W-77
W-71
6.8 bar (98 PSI)
803 g (1.77)
673 g (1.49)
82.1 dB(A)
74.8 dB(A)
G1/4" M
G1/4" M
G3/8"M
G1/4" M
Atmosphere 5 ~ 40 °C / Air-Fluid 5 ~ 43 °C
0
480
430
1
255
185
2
345
250
3
3.5
435
325
1
285
185
2
390
250
3
485
325
0
3.5
200
240
1S
95
75
2S
135
85
3S
180
165
4S
195
230
21S
140
195
31S
170
230
3.0
1G
110
75
2G
155
85
3G
210
165
4G
220
230
21G
160
195
31G
190
230
Sparks and open flames are strictly prohibited. Paints can be highly
flammable and can cause fire. Do not expose to open flames, electrical
goods, cigarettes etc.
Securely ground spray gun using conductive air hose. (<1MΩ). Always
ensure that the spray gun is earthed correctly.
PROTECTION OF HUMAN BODY
Use in a well-ventilated site, using a spray booth. Poor ventilation can
cause organic solvent poisoning and fire.
Always wear protective gear (safety glasses, mask, gloves) to avoid
inflammation of eyes and skin. In case of any physical discomfort, imme-
diately seek medical advice.
Wear earplugs if necessary. Noise level can exceed 85 dB(A), depending on
operating conditions and painting site.
Pulling the trigger many times during operation, may cause carpal
tunnel syndrome. Always rest, in case of tiredness.
IMPROPER USE
Never point gun towards people or animals.
Never exceed maximum working pressure or maximum operating
Temperature
Always release air and fluid pressure before cleaning, disassembling
or servicing. Otherwise, remaining pressure can cause bodily injury due to
improper operation or scattering of cleaning liquid.
Tip of fluid needle set has a sharp point.
Do not touch the tip during maintenance to avoid accidents.
Never use this gun to spray foods or chemicals. Otherwise, foreign
substance, could cause corrosion of fluid passages which could adversely
affect health.
Never alter this spray gun, to avoid insufficient performance and damage.
If something goes wrong, immediately stop operation and find the
cause. Do not use again, until you have solved the problem.
Do not enter working areas, where robots, reciprocators, etc. are used,
until they have been turned off. Otherwise, they could cause injury.
445
210
3. HOW TO CONNECT
255
280
CAUTION
230
Use clean air filtered through air dryer and air filter.
290
When using this gun for the first time after purchase, adjust fluid
330
needle packing set, spray cleaner to clean fluid passages and remove
190
rust preventive oil.
100
Firmly fix the paint supply hose or a suitable container to spray gun, to
135
avoid that disconnection of it, can cause bodily injury.
170
1. Firmly connect air supply hose to air nipple G1/4"(13).
200
2. Firmly connect paint supply hose or suction cup to fluid nipple
155
G 3/8"(W-77) and G 1/4"(W-71).
170
3. Flush fluid passages with a compatible cleaner.
120
4. Pour paint into container, test spray, adjust fluid output and pattern width.
155
4. HOW TO OPERATE
185
230
Suggested atomizing air pressure varies according to each model, and it is
165
listed in the Specifications Table. (see left)
185
Recommended paint viscosity differs according to paint property and pain-
ting conditions.
Set the spray distance from the gun to the work piece, as near as possible
within the range of:
200 ~ 250 mm (8 ~ 10 in) (W-77) and 150 ~ 200 mm (5.9 ~ 7.9 in) (W-71)
The gun should be held so that it is perpendicular to the surface of the work-
piece at all times. Then, the gun should move in a straight and horizontal
line. Arcing the gun causes uneven painting.