2) Briefly press the PROG button on the RTS control point (b) to be added or
removed:
The heating lamp comes on then goes out; the RTS control point has been
added/removed.
3.3 Creating multiple or group controls
3.3.1 Group control
Group control: an RTS control point controls several Heating Mod/Var Ramp
RTS-HR1s.
1) Switch off the power supply to the Heating Mod/Var Ramp RTS-HR1 (c, d
and e) to be controlled by a single RTS control point.
2) Switch on the power supply to the first Heating Mod/Var Ramp RTS-HR1
(e) to be linked to the RTS control point.
3) Simultaneously press the Up/Down buttons on the RTS control point: the
heating lamp comes on then goes out.
4) Press the PROG button on the RTS control point: the heating lamp will
come on then go out again to indicate that the RTS control point has been
programmed into the Heating Mod/Var Ramp RTS-HR1.
5) Switch off the power supply to the newly linked Heating Mod/Var Ramp
RTS-HR1 (c) before adding the next Heating Mod/Var Ramp RTS-HR1.
6) Switch on the power supply to another Heating Mod/Var Ramp RTS-HR1
to be linked and repeat steps 3), 4) and 5) for each Heating Mod/Var Ramp RTS-HR1 (d, e, etc.).
7) Switch on the power supply to all the Heating Mod/Var Ramp RTS-HR1s linked to the RTS control point.
3.3.2 Multiple control
Multiple control: a Heating Mod/Var Ramp RTS-HR1 is controlled by several
RTS control points.
Caution! A maximum of 12 control points may be programmed into a Heating
Mod/Var Ramp RTS-HR1.
1) Press the PROG button on the programmed RTS control point (a) until the
heating lamp comes on then goes out: the Heating Mod/Var Ramp RTS-
HR1 will be in its programming mode for 2 minutes.
2) Briefly press the PROG button on the RTS control point (b) to be added:
The heating lamp comes on then goes out; the RTS control point has been
added/removed.
Repeat these two steps to add each RTS control point.
4. Tips and recommendations
4.1 Problems with the Heating Mod/Var Ramp RTS-HR1?
Problems
The
Heating
Mod/Var
Ramp RTS-HR1 cannot
be operated by pressing
one of the buttons on the
RTS control point.
The
Heating
Mod/Var
Ramp RTS-HR1 does
not heat up sufficiently.
Possible causes
The power supply is faulty.
The RTS control point has not been
programmed
into
Mod/Var Ramp RTS-HR1 .
The RTS control point used is not
compatible with the Heating Mod/Var
Ramp RTS-HR1.
The batteries in the RTS control point
are weak.
The correct distance and height of the
installation have not been respected.
Solutions
Check the power supply.
Follow the procedure for programming
the
Heating
an RTS control point.
Ensure
compatible.
Replace the batteries with identical
ones.
Check the distance and height of the
installation.
11
the
two
products
are