OPERATION
• Flush triggered by user's departure.
TECHNICAL CHARACTERISTICS
ELECTRONIC URINAL VALVE
Electrical supply:
• Mains versions (ref. 428150 & 428200):
- 220-240V/50-60 Hz class II (without earth).
- The installation must conform to local Electrical Regulations/Standards and must be installed by a competent,
qualified electrician.
- If the supply cable is damaged, the installer must replace it.
- Order a transformer ref. 406000 or 406220 separately.
- Connect the sensor to the RMB terminal: red wire to the R terminal, screen wire to the M terminal and white cable
to the B terminal (Fig. H page 3).
• Battery-operated versions (ref. 428156 & 428206):
- 2 Lithium 3V batteries are supplied in the box.
- The ambient temperature should be ≥ 5°C to ensure batteries function correctly.
- The IP65 waterproof electronic housing IP65 (Fig. B & C page 7).
- Connect the sensor to the RMB terminal: red wire to the R terminal, screen wire to the M terminal and white cable
to the B terminal (Fig. G page 8).
- To connect the solenoid valve to the electronic unit, the red wire must be connected to the
and the black wire to the
• Secure the cables in place with a fixed router e.g. a rigid sheath or cable holder.
• Maximum ambient operating temperature: 40°C.
Hydraulic supply:
• The arrow engraved on the solenoid indicates the direction of the water flow
• Pressure: 1 - 5 bar (100 - 500kPa), 3 bar recommended (300kPa).
• Base flow rate for a standard urinal: 0.15 L/sec
• TEMPOMATIC flow rate: 0.32 L/sec at 1 bar, 0.45 L/sec at 2 bar, 0.5 L/sec at 3 bar.
• Calculate sizing of pipes using probable flow rates and dynamic pressure.
INSTALLATION
• To avoid interference from infrared beams do not install the electronic valves opposite a shinny or bright object.
Do not install two electronic valves opposite each other.
• Do not cut or lengthen the detector cable.
• THE INTEGRITY OF THE SEALS BETWEEN THE WALL PLATE OR STAINLESS STEEL WALL PLATE
AND THE WALL MUST BE CHECKED AT LEAST ONCE A YEAR, AND MADE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall. DELABIE cannot be held responsible
for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT UK: 01491 821821.