Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Technical Data - Cooke & Lewis CHS50 Anweisungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26

Installation

All installation must be carried out by a competent person or qualifi ed electrician. Before connecting
the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
The appliance must be connected directly to the mains using an omnipolar circuit breaker with a
minimum opening of 3mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it complies
with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage. If the supply cord is damaged, it must
be replaced by a special cord or assembly available from the manufacturer or its service agent.
WARNING: This is a Class II appliance and MUST NOT be earthed
This appliance is supplied with a 2 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral.
EUR
N
L
N
(Blue)
L
(Brown)
The fuse must be rated at 3 Amps.
To avoid the risks that are always present when you use an electrical appliance it is important that
this appliance is installed correctly and that you read the safety instructions carefully to avoid misuse
and hazards. Please keep this instruction booklet for future reference and pass it on to any future
owners. After unpacking the appliance please check that it is not damaged. If in doubt, do not use the
appliance but contact Customer Services.
The manufacturer declines all liability for damage caused to persons and objects due to incorrect
or improper installation of the appliance. Any permanent electrical installation must comply with the
latest wiring regulations applicable to your country and for your own safety a qualifi ed electrician or
contractor should undertake the electrical installation.
The appliance is supplied from the factory to use external ducting (not supplied). Should you wish to
use this in recirculation mode only, please fi t the correct carbon fi lter (not supplied).

Technical data

Supply voltage
Power consumption - Fan
Power consumption - Luminary
Power consumption - Total
UK
N
L
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
FUSE ON
USE A 3AMP FUSE
220-240V~, 50Hz
95W
5.5W Max
100.5W

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis