STORAGE AND TRANSPORT

Store the heat pump in an upright position, in a clean and dry place.
Always transport the heat pump in an upright position; exceptionally, it may be tilted by 35
all directions. Be careful not to damage the housing or the vital component parts of the heat pump
during transport.
THE PRINCIPLE OF OPERATION
The heat pump is in fact a thermodynamic heat generator, drawing heat from a low temperature level (e.g.:
heat from the ambient air) to a higher temperature level (e.g.: hot sanitary water).
The heat drawn from the ambient air, along with the electric energy, generate heating energy, which is
available for heating the sanitary water.
2/3 Heat from
ambient air
PLACING
Install the heat pump in a dry place, with a temperature range from 10 to 35°C, at least 20m
for version without air inlet). Make sure the temperature in the inlet air room is never below freezing.
In general, we recommend a spacious and well-ventilated room with a temperature range of between 20
and 25°C, which are optimum conditions for operation of the heat pump.
Also, when selecting the location for installation of the heat pump, make sure that the place (place of air
inlet) you selected is not dusty, as a dusty environment can have adverse effects on operation of the heat
pump. Be careful when selecting the wall for mounting the heat pump: the wall must be strong enough to
bear the load (the weight of the heat pump and of the water in the boiler). Take into account all the
measurements in order to prevent dissipation of noise and vibrations through the walls into other rooms
(bedroom, living room).
Also, do not place the heat pump (with air inlet) in places where other air consumers are installed (gas
boiler, fireplace fuelled with solid fuels, suction devices, etc).
Evaporator
Compressor
Flow control
element
Chart of energy flow through the heat pump unit
1/3
Electric
energy
Condenser
60
Produced hot
sanitary water
o
+55
C
3
in area (only
o
in