Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating
Room temperature
SN-ST
+10°C to +38°C
SN-T
+10°C to +43°C
Do not operate the appliance outside the
specified room temperature range.
Setting up
• Standard EN 378 specifies that the room in which you install
your appliance must have a volume of 1 m
refrigerant used in the appliance, so as to avoid the formation
of inflammable gas/air mixtures in the room
where the appliance is located in the event
of a leak in the refrigerant circuit. The quan-
tity of refrigerant used in your appliance is
indicated on the type plate on the inside of
the appliance.
• Only use the appliance when it is installed.
Do not cover ventilation openings
•
or grille.
Removing the transportation
safety component
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type
plate. The position of the type plate is shown in the section entitled
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating current/three-
phase current) or energy-saving plugs. Risk
of damage to the electronic control system!
64
Operating and control elements
The electronic control panel has the "touch capacitance tech-
nology".
Any function can be activated by touching the corresponding icon.
1
2
3
4
5
6
per 8 g of R 600a
3
Symbols in the display
Switching the appliance on and off
Switching the appliance on
Press the On/Off button until the temperature display
lights up.
Switching the appliance off
Keep the On/Off button pressed for approx. 3 seconds so that
the temperature display goes out.
Temperature display (display)
Temperature setting buttons
On/Off button
Action Cool button (The Action Cool button switches the re-
frigerator compartment to maximum cooling)
Audible warning on/off button
Fan button (IK293 S only)
Setup mode is activated (activating the child lock)
Child lock is activated
Symbol ActionCool on
Fan ON symbol (IK293 S only)
Demo mode is activated