9.4 - CLOSING ENDSTOP - FAST gearmotors
The closing endstop only activates the deceleration and is set FOR GATES WITH LEAVES OF 1.20 TO 2.30 M WIDE.
WARNING! this setting must always be made only after you have adjusted the opening endstop.
Closing
To adjust the microswitch,
deceleration
L = 1.20 < 2.30 m
Upper cam fi xing and
locking/release screws
If, however, the gate leaf MEASURES LESS THAN 1.20 METRES, before going on, you need to:
- remove the 2 screws that are fi xing
the upper cam;
- extract the cam and replace it in the
same position but upside down (the
dimensions of the switch's activating
template change).
Closing
So, to set the microswitch,
deceleration
L = < 1.20
- manually push the gate leaf to the fully closed position;
- release the upper cam and turn it clockwise until the switch is released as
shown in the fi gure;
- lock the cam in this position.
Microswitch
Upper cam
fi xing screws
- manually push the gate leaf to the fully closed position;
- release the upper cam and turn it clockwise until the switch is released as
shown in the fi gure;
- lock the cam in this position.
Upper cam
Switch
Upper cam
Switch