6.5 - ELECTRICAL LOCK
ZL180 lets you connect, in two different modes, a 12V (15W max) electrolock and, if necessary, also activate the "Ram Blow" function.
Mode 1 – Excludes use of the 2nd radio channel on B1-B2; after
connecting it, operate as follows:
a) - Set dip switch 6 to ON (and dip switches 1, 2, 3, 4, 5
to OFF); ;
b) - press CH1: the red PROG led will start to blink;
c) - when the led stays on (after about 5 seconds) the
procedure is complete;
d) - set to the dip switches back to OFF (or to the previous
position, which depends on the functions selection, see
paragraph 7, page 12).
N.B.: to return to default (2nd radio channel on B1-B2), follow
the same procedure while pressing CH2.
b)
Mode 2 - Does not allow connection of an
indicator lamp on 10-5; after connection it:
a a ) - Set
) - Set dip switches 2 and 6 to ON
dip switches 2 and 6 to ON (and
dip switches 1, 3, 4, 5 to OFF); ;
b b ), ), c c ), ), d d ) - continue with the above
) - continue with the above COMMON
PROCEDURE.
PROCEDUR
N.B.: to return to default (indicator lamp on 10-5),
follow the same procedure while pressing CH2.
In both modes, to activate the "ram blow"
a a ) - Set
) - Set dip switches 3 and 6 to ON
dip switches 3 and 6 to ON (and dip switches 1, 2, 4, 5 to OFF); ;
b b ), ), c c ), ), d d ) - continue with the above
) - continue with the above COMMON PROCEDUR
N.B.: to exclude the ram blow, follow the same procedure while pressing CH2.
(1)
Upon each opening command, the gate leaves press on the closing jamb for one second,
assisting the electrolock release operation.
COMMON PROCEDURE
c)
COMMON
a)
(1)
:
COMMON PROCEDURE.
a)
place
a 3.15 A
fuse in between
a)
RALL1
transformer
terminal
B2
B1
10
d)
RALL1
transformer
terminal