Brief instructions BAT 171
Keys
Functions
Cursor
R Line selection.
R Change of setting / value within a line.
Enter
R Storage of setting or value selected.
R Start of application, e.g. battery test.
Back / Print
R Return to previous display
R Print test result.
Menu,
R Call-up of main menu with <MENU> key
e.g. to alter language (4th entry from top).
R Switch-on and switch-off (without connection
to 12 V battery)
1. Connect the red clip of the battery connecting cable to the
positive post (+) of the 12 V battery.
2. Connect the black clip of the battery connecting cable
to the negative post (-) of the 12 V battery.

3. BATTERY TYPE:

Select NORMAL or VRLA with
4. BATTERY STANDARD:
Select the standardization system of the 12 V battery
with
and
i
Hold
and
i
Heed the information on additional prompts during the
battery test.
5. BATTERY RATING (depending on BATTERY STANDARD
selected): Select the characteristic value with
press
.
? The battery test (TESTING) is started.
"
The following are displayed after several seconds:
$
Battery status (test result)
$
Battery voltage measured
$
Standardization system selected (battery type)
$
Battery power value measured
Test result
GOOD BATTERY
GOOD, RECHARGE Fully charge the battery and repeat the battery test.
REPLACE BATTERY Replace the battery and repeat the battery test.
ON / OFF
and press
to scroll more rapidly through the values.
Explanation
No action required.
Replace the battery if the message "GOOD,
RECHARGE" is displayed again after full charging.
The message "REPLACE BATTERY" may also be
displayed in the event of poor contact between
the battery clips and the battery.