2) P7100 XL /P7200 XL Flush valve ND20 - G3/4" EN 12541 compliant
3) PRECAUTIONS FOR USE (The product guarantee depends on the respect for these rules)
INSTALLATION and START UP
For products delivered with filters, these must be installed in accordance with the instructions.
Before commissioning any of our valves, it is essential to carefully drain the pipes that can damage the mechanisms or water passages (PRESTO® heads that can be
dismantled from front).
Recommended operating pressure according to NF EN 816: 1 to 5 bars.
CLEANING
The chrome-plated coating of PRESTO® valves must be cleaned only with soapy water.
Abrasive, acid, alkaline or ammonia-based household products are prohibited.
4) Part no. 55500 Complete concealed valve mains powered
Part no. 55501 Complete concealed valve battery powered
5) Technical characteristics:
- Connection male thread G3/4"
- 1/4 turn stop valve
- Automatic flow regulator.
- Adjustable supply volume: 6 to 9l. (Supplied set to 6l) (P1000 XL version)
- Outlet connector for tube PVC Ø28x2 (part no. 47850).
6) Part no. 55512 Stainless steel front plate P7100 XL transformer
7) Part no. 55511 Stainless steel front P7200 XL battery
8) Part no. 55513 - Concealing box P7100 XL Class II, Mains powered
Part no. 55513 - Concealing box, P7200 XL Class II, Battery powered
9) Transformer (not supplied) (230V /12 A C)
Installation on DIN rail
- For 1 to 3 valves (18VA) Part no. 90464
- For 4 to 6 valves (35 VA) Part no. 90711
- For 7 to 10 valves (75 VA) Part no. 90610
In IP 65 waterproof case
- For 1 to 3 valves (18 VA) Part no. 90685
- For 4 to 6 valves (35 VA) Part no. 90704
- For 7 to 10 valves (75 VA) Part no. 90686
10) Installation
11) Detection area
12) Flush tube Part no. 47850 not supplied
13) Flush tube Min. Height: 500 mm
14) Installation of the concealing box
15) Bleed the installation before installing the valve
16) Left or right inlet
17) Sealing
18) Protection plate
19) Torx No. 15 screwdriver
20) Tiles
21) Installation of P7100 XL and P7200 XL front plate
22) Battery version Part no. 55511
23) Green or black tube Ø4 - Lg = 0.25 m
24) Connect on inlet arrow
25) White tube Ø4 - Lg = 0.25 m
26) White tube connection
27) Connect on outlet arrow
28) 1 - Install the white tube as shown on the diagram 2 - Install the green or black tube
29) Mains version Part no. 55512
30) Power cord, 12V- AC
31) Flow rate (l/s)
32) Flow rate diagram
33) Pressure (bars)
34) Operating mode
35) Manual mode
36) Display LED
37) - Continuously lit
38) - Rapid flashing
39) - Slow flashing
40) - Series of flashes (1 to 4 flashes)
41) PRESTO electronic WC flush valve offers both automatic and manual operation
42) Manual mode:
- Pressing the manual control releases a 6l flush.
- When the user leaves, the automatic mechanism is disabled, so the flush is not activated.
43) Automatic mode (if manual push mode is not used)
After 15 seconds' presence, the system is activated
The flush is triggered 2s after the end of user detection.
If the presence time is less than 60s, the system automatically triggers a 6l flush.
If it is in excess of 60s, the system triggers a standard flush
(6l or 9l depending on the selected programme).
44) Automatic flush: A 6l automatic flush is carried out every 72 hours.
45) Available programmes
The valve has four operating programmes. It is supplied with programme 1
Programme no.
1
2
3
4
Volume selection: Depends on bowl used
Range selection: The standard range provides proper operation for most installations.
However, in highly-reflective and/or confined spaces, the short range option may be required to prevent reflections from doors
or walls disrupting proper operation of the product.
46) 60-second water flow shutoff to allow maintenance
47) Changing the active programme
48) Holding the reflector in front of the cell causes the valve to flash slowly
and shuts off water flow – it then starts flashing quickly (at which point the reflector should be withdrawn).
The number of flashes emitted by the tap corresponds to the number of the active programme.
49) Programme no.
50) Programme no. + 1
51) New Programme no.
Wash volume
9l
Standard (approx. 900 mm for white background)
6l
Standard (approx. 900 mm for white background)
9l
Short (approx. 700mm for white background)
6l
Short (approx. 700mm for white background)
Detection range