NOTE!
For a secure seal, apply thread sealant to the fitting threads, according to the maker's
instructions. Do Not use Teflon tape as a thread sealer, as small particles of the tape may
break off and block the small air passages in the torch. Connect as follows:
Installing Optional Two - Stage Air Filter Kit
This optional two - stage air line filter is also for use on compressed air shop systems. Filter removes moisture and
contaminants to at least 5 microns.
Connect the air supply as follows:
1. Attach the Two Stage Filter bracket to the back of the power supply per instructions supplied with the filter
assembly.
NOTE!
For a secure seal, apply thread sealant to the fitting threads according to manufacturer's
instructions. Do Not use Teflon tape as a thread sealer as small particles of the tape may
break off and block the small air passages in the torch.
2. Connect the two stage filter outlet hose to the inlet port of the Regulator / Filter Assembly.
3. Use customer - supplied fittings to connect the air line to the Filter. A 1/4 NPT to 1/4" hose barbed fitting is
shown as an example.
Manual 0-5397
Hose Clamp
Gas Supply
Hose
Optional Single - Stage Filter Installation
INSTALLATION
ESAB CUTMASTER 100
Regulator/Filter
Assembly
Inlet Port
Art # A-07944
1/4 NPT to 1/4"
(6mm) Fitting
3-3