Troubleshooting
The device indicates no function.
The cables to the reversing light are not connected or are not properly con-
nected.
The plugs for the sensors are not connected or are not properly plugged into
the control electronics.
➤ Check the plugs, and make sure they lock into place.
Error tone for three seconds after engaging reverse gear
One or more sensors are defective or no longer connected to the control
electronics. The display shows the defective sensor:
For example E1 for sensor 1
Sensor 1 has the shortest connection cable, sensor 4 the longest.
EE if more than one sensor is defective
➤ Check the plugs, and make sure they lock into place.
➤ Replace the defective sensor(s).
Caution!
The system does not work if one or more sensors are defective.
Device indicates obstacles incorrectly.
False alarms may have the following causes:
Dirt or frost on the sensors
➤ Clean the sensors.
The sensors were fitted too low.
➤ Adjust the position of the sensors.
The sensors have contact with the chassis.
➤ Disconnect the sensors from the chassis.