Constraints

Please observe the following before any temperature measurement to ensure a stable and reli-
able result:
- Push back hair from the forehead.
- Wipe away any perspiration from the forehead.
- Avoid any drafts (e.g. from nasal specs, air conditioning...).
- Allow a 1 minute interval between two measurements.
- The thermometer cannot be used as long as the display screen is not switched off.
- Each time there is a significant change in the ambient temperature due to a change in environ-
ment, to allow the ThermoFlash® LX-260T EVOLUTION to acclimatise to this ambient tempera-
ture for at least 15 minutes before using it.
IV. FUNCTIONS
1. Specially designed to take the body temperature of a person regardless of the room temperature.
2. Quick and reliable results as it use the HEIMMANN infrared detection system.
3. Vocal indication of measurements and color indicators to quickly display and interpret the
diagnosis of the temperature obtained.
4. Display measurement results:
Measurement range from 32.0 to 42.9°C (89.6 to 109.2°F).
Hi displays when the result is above 42.9°C (109.2°F).
Lo displays when the results is below 32.0°C (89.6°F).
5. Sound alarm if temperature is exceeded.
6. Memorization of the 32 last measures.
7. Measurement and display of room temperature:
Measurement ranges from 5.0°C to 59.9°C (41.0°F to 139.8°F).
8. LCD back-lighted digital screen.
9. Data displayed in Celsius or Fahrenheit.
10. Automatic stop (energy saver).
11. Small, convenient, easy to use.
Additional uses:
The ThermoFlash® LX-260T EVOLUTION can also be used to measure the temperature of a
baby-bottle or bath, or room temperature (by using the SURFACE TEMP or ROOM function). This
function is in accordance with the Directive 89/336/EEC Electroma-gnetic Compatibility.
20
Visiomed - LX-260TE - 032017
V. DESCRIPTION OF THE THERMOFLASH® LX-260T EVOLUTION
SEE SCHEMA
PAGE 2.
B
1
Infra-red lens
2
LCD screen
4
Battery case
5
Infra-red sensor
VI. STARTING UP YOUR THERMOFLASH® LX-260T EVOLUTION
1. Install battery
2. For the first use or when inserting new batteries wait between 10 minutes for the warm-up of
the apparatus and when inserting the new batteries.
3. Aim towards the forehead (see
A
for the ThermoFlash® LX-260T EVOLUTION positioning),
from a distance of 2-5 cm, press the measuring key, the temperature is displayed in 1 second.
The temperature can also be taken behind the ear lobe.
4. Before taking the temperature, make sure to remove hair and perspiration from the forehead.
You can also take the temperature behind the ear lobe.
5. Replace new battery when you see the lower battery logo
VII. SETTINGS
1. Choosing the temperature mode
The ThermoFlash® LX-260T EVOLUTION is specially designed to measure body temperature
without contact, of children or adults. It can be used by consumers in household environment
and doctors in clinic as reference. For this, use the BODY mode.
Measurement range for BODY mode: 32°C – 42.9°C (90°F – 109°F).
Note : You can also use the ThermoFlash® LX-260T EVOLUTION to measure the temperature of an
area or an object, food, a liquid or a room temperature. For this, use the SURFACE TEMP mode.
Measurement range for SURFACE TEMP mode: 0°C – 60°C (32°F - 140°F).
By selecting the ROOM Mode, it will display the ambient temperature of the room you are in.
Press the MODE button for one second, the screen will display: BODY for the body measurement
temperature. Press the MODE button again to switch to SURFACE TEMP or ROOM mode.
Note: The ThermoFlash® LX-260T EVOLUTION is automatically set to BODY.
Important: The surface temperature differs from the internal body temperature. To obtain the
internal temperature, always use the BODY mode.
Please make sure to select the BODY mode for an internal temperature reading and the SURFACE
TEMP mode or the ROOM mode for an external area reading (bottle, bath, room...).
2. Choosing the temperature unit
Press the °C/°F button to select the temperature unit. The symbol of the chosen temperature unit
is displayed (°C for Celsius degrees and °F for Fahrenheit degrees).
Visiomed - LX-260TE - 032017
3
Measure button
6
Setting buttons
.
21