The display shows a "H" as long as the temperature remains above 60°C.
6. Safety cut-out
If one or more burners are accidentally left on, the control automatically turns them off after a certain time has
elapsed. The table below indicates the time interval, which depends on the power level setting.
Level
1
2
3 – 4
5 – 6
7 – 8
9
P
If the safety cut-out has tripped, the symbol "H" is displayed.
To avoid the automatic cut-out being tripped, simply touch the burner selection key or the "+" or "-" keys before
the time runs out.
7. Booster functions( Fig 11)
The "booster" function for the ∅210 mm burner is enabled by touching the "Booster" key (8) regardless of the
selected power level. When this function is enabled, the display shows the letter P.If the power delivered to the
other ∅ 145 mm burner exceeds 600W, this is automatically reduced to 600W. The corresponding indicator begins
to display the new lower power setting and the previous power setting alternately.
8. System temperature control
A temperature sensor situated inside the cook top's cooling unit constantly measures the temperature of the
generator's electronic circuits. In the event of these circuits overheating, the system reacts as follows:
The display related to the induction plates shows the power levels alternatively with the symbol "c".
The overheating of the circuits definitely indicates an anomaly and means that the cook top has not been installed
properly, or the openings for air circulation are not large enough
9. Pan sensor
Each burner is complete with its own sensor for detecting the presence of a pan.
The system is fine-adjusted to recognize the presence of a pan that, according to the scale of the EN standards, is
one size smaller than the nominal diameter of the burner.
If no pan are detected or if an aluminium pan is detected, the power level flashes on the heater display. After 30
seconds the power levels returns to 0.
If the power level symbol flashs also when a pan is actually on the burner, this generally means that the size or
shape of the pan concerned is unsuitable. In this case, check whether the type of pan is suitable for induction
cooking (see the pan manufacturer's trademark or instructions).
10. System self test
When the system is connected to the power supply (during installation or after a power cut), a self-test message
appears for 1 second on the displays relating to the burner power settings.
If a different code appears or the display remains blank, this means there is a problem with the power supply or
some malfunction in the system. In this case, it is best to check the installation again.
FAULT CODES MESSAGES
CODE
DEVICE
F – 1
Heater temperature sensor
(heater)
F – 2
Heater temperature sensor
(heater)
F – 3 (on two
Power temperature sensor
different displays)
(induction generator)
F – 4 (on two
Power temperature sensor
different displays)
(induction generator)
F – 5 (on two
Touch control wiring
different displays)
F – 9 (on two
Induction generator
different displays)
c
Induction generator
Time limit (hours)
10
5
4
3
2
1
10 min.
FAULT
Short circuited
Open circuited
Short circuited
Open circuited
Loss of communication
between
Tc and generator
Overcurrent
Overheating
AUTOMATIC ACTION
The corresponding heater turns off. The +/-
keys are locked
The corresponding heater turns off. The +/-
keys are locked
The two corresponding heaters turn off. The
related +/- keys are locked
The two corresponding heaters turn off. The
related +/- keys are locked
All the heaters are switched off. The related
+/- keys are locked
The two corresponding heaters turn off. The
related +/- keys are locked
-