Herunterladen Diese Seite drucken

Technical Characteristics; Installation Instructions; Laws, Standards, And Technical Regulations - Diamond BBRV Installations-, Betriebs- Und Wartungsanleitungen

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
2.4

TECHNICAL CHARACTERISTICS

CARRYING STRUCTURE in stainless steel AISI 304 with adjustable feet.
GAS COOKERS
DRIP TRAY also in stainless steel AISI 304.
PAN-SUPPORT GRATES for burners in enamelled cast iron
COLLECTION BOWL under grates in enamelled steel.
NICKEL PLATED CAST IRON BURNERS with brass primary air regulator.
BURNER HEADS in drop forged brass with stabilized flam.
EQUIPPED BY FIXED INJECTOR for mean burner, pilot burner and by-pass for pilot suitable for every kind of gas.
GAS TAPS in drop forged brass with safety valve and thermocouple and gassupply for pilot bumer; safety valve close the
gassupplies in the case of extinction of the pilot burner.
TAP KNOBS in heat resistant material.
GAS STOCKPOT STOVE BBRV
- Carrying structure in stainless steel AISI 304 18/10, with adjustable feet.
- Drops collector in stainless steel.
- Grates for burners in enamelled cast iron.
- Cast iron burners, with stabilized flame, equipped by fixed injectors, suitable for every kind of gas.
- Gas taps in printed brass, operated by knob in thermosetting material.
- Work plane in safety: all the ranges can be furnished also with the work plane equipped of safety device.
- Each burner is provided of safety valve with thermocouple and pilot flame; "Targhet".
3.
All installation and adjustment operations must be carried out by qualified personnel according to the regulations in force.
(See tables of technical characteristics on pages 8-9-10-11).
NOTES:
- If the unit is installed against a wall, the wall must be able to resist temperatures of 80°C and must be incombustible
- If only one unit is installed, we recommended that you secure it to the floor. The weight of the equipment to be positioned
must be considered.
- Positioning of the inlets (gas, water and electricity) are indicated on the installation drawings .
PRELIMINARY PREPARATION
Before proceeding to installation, remove the protective plastic film, and eliminate any adhesive residues using a suitable
product for cleaning stainless steel.
3.1

LAWS, STANDARDS, AND TECHNICAL REGULATIONS

During installation, the following regulations in force must be observed:
- Territorial building ordinance and fire-prevention regulations.
- Safety regulations; safety at work.
- Prescriptions made out by the gas suppliers to whom you should apply also for acknowledgement of admissibility of
arrangements set on for your appliance installations.
- Installation of gas-fed appliances Normes, if any.
- Heath regulations.
- Ventilation standards.

INSTALLATION INSTRUCTIONS

- 17 -
GB

Werbung

loading

Diese Anleitung auch für:

Rf1gRf2gEervRf3g