EN
SLOW DOWN
7
CLOSING SPEED
8
STEP BY STEP
MOTOR 2
9
DELAY
SLOW DOWN
10
LENGTH
11
ENERGY SAVING
12
BLACK OUT
* For SUN4024 sliding gate motors the parameter will be DEFAULT 1 - MIN 1 - MAX 2
** For SUN4024 sliding gate motors the parameter will be DEFAULT 15 - MIN 15 - MAX 100
4.8 - NIGHT LIGHTS
The night lights function automatically with the Eclipse flashing light
connected appropriately.
PARAMETERS
1
AUTOMATIC LIGHT
2
LIGHT INTENSIVITY
EXTERNAL LIGHT
3
LEVEL
LIGHT SWITCH-OFF
4
TIMER
The Night Light System switches the lights on or of 15 minutes
after the set threshold is exceeded. This delay is to prevent false
24
Motor speed during closing deceleration phase.
1 = minimum
2 = low
3 = medium
4 = high
5 = maximum
SBS configuration:
0 = Normal (OP-ST-CL-ST-OP-ST...)
1 = Alternate STOP (OP-ST-CL-OP-ST-CL...)
2 = Alternate (OP-CL-OP-CL...)
3 = Apartment block – timer (always opens)
4 = Apartment block with immediate reclosure (always
opens. Closes if gate is open)
Leaf 2 opening delay with gate closed
0 - 60 sec.
Deceleration distance
0 = Customised decelerations
1 to 100 = Motor deceleration percentage during
opening and closure. With KUBE, programmable
deceleration during opening and closure will be
individually adjustable for each engine
Energy saving: enables photocell switch-off when gate
is closed
0= disabled
1= enabled
0 = OFF
1 = When the power line is restored, the motor will
automatically re-close
DESCRIPTION
0 = Night Light System deactivated
1 = Night Light System active (automatically activated
during learning of the stroke with the ECLIPSE flashing
light connected)
1 to 5 = Brightness at which LEDs switch on during the
night
1 = Light sensor tripped with low outdoor light
2 = Light sensor tripped with medium outdoor light
3 = Light sensor tripped with bright outdoor light
0 = OFF (automatic lights)
From 1 to 12 = time for which lights remain on from
automatic activation of Night Light System
1 *
0
2
20 **
0
0
To customise, proceed as follows:
14A
NIGHT LIGHTS
DEFAULT
0
3
2
0
switch-on or switch-off due to external light sources such as car
headlights.
1
5
0
4
0
60
% (step
0
100
of 1)
0
1
0
1
MIN.
MAX.
UNIT
0
1
1
5
1
3
0
12
hours
s