Maintenance and cleaning

WARNING! RISK OF INJURY! Disconnect the
appliance from the compressed air supply.
CAUTION!
Before maintenance, clean off any hazardous substances that
may (due to working processes) have accumulated on the
appliance. Avoid all skin contact with these substances. If the
skin comes into contact with hazardous dusts, this can lead
to severe dermatitis. If dust is produced or swirled up during
maintenance, it can be inhaled.
NOTE
To ensure correct functioning and long-term durability of the
compressed air polisher, pay attention to the following points:
Sufficient and continuously intact oil lubrication is highly import-
ant for optimum functioning.
Check the speed and vibration levels after each use.
Check the idle speed regularly and after any maintenance is
performed:
use a rev counter and perform the measurement without any
clamped tools. At a residual pressure of 6.3 bar, the idle speed
may not be exceeded under any circumstances.
If the appliance is exhibiting excessive vibration levels, the cause
of the vibrations must be identified and repaired.
Use only the genuine replacement parts recommended by the
manufacturer, otherwise you could put users at risk. In doubt,
contact the Service Centre.
Check the polishing disc
Clean the appliance with a soft, dry cloth only.
Never use sharp or abrasive cleaning agents under any circumstances.
GB │ IE │ NI
18 
regularly for damage.
PDAP 75 A1