4. Commissioning
To commission the motor, an RTS control point must be
programmed.
Caution! Only one motor can be powered at a time!
Caution! Do not use the Inis RT/Inis RTS control point for
commissioning!
4.1 Pre-programming the RTS control point
1)
Switch on the power supply.
2)
Simultaneously press the Up/Down buttons on the RTS
control point:
The roller shutter makes an up and down movement,
the control point has been pre-programmed in the
motor.
4.2 Controlling the direction of rotation
1)
Press the up button on the RTS control point:
a)
If the roller shutter is raised, the direction of rotation
is correct:
Move onto the section entitled "Setting the end
limits".
b)
If the roller shutter is lowered, the direction of rotation
is incorrect:
Move onto the next step.
2)
Press the RTS control point STOP/my button until the
roller shutter makes an up and down movement:
The direction of rotation has been modified.
3)
Press the RTS control point Up button to check the direc-
tion of rotation.
4.3 Setting the end limits
Setting the end limits depends on the type of connections
and bolts used as well as whether or not there are stops on
the end slat.
4.3.1 With bolts and stops on the end slat
If the roller shutter is fitted with bolts (F) and stops on the
end slat (G), the end limits are automatically adjusted after
the following procedure has been carried out:
1)
Press the up and down buttons until the roller shutter
moves up and down.
2)
Press the STOP/my button until the roller shutter moves
up and down.
The end limit positions have been programmed.
3)
Press the RTS control point PROG button to program the
first control point:
The roller shutter moves up and down briefly.
Copyright © 2008-2009 Somfy SAS. All rights reserved.
1
2
ON
1
Setting the end limits
a
move onto the next
b
2
3
F
G
1
2
3
PROG.
Oximo RTS
step
47