GB
IE
4.
Plug the suction tube (12) onto
the rigid end piece of the suc-
tion hose (11).
Switching on/off
Connect the mains plug.
The equipment is fitted with a
safety stop, which allows operation
only with the pleated filter and wire
filter basket installed correctly.
Switching On:
On/Off Switch (see
Switching Off:
On/Off Switch (see
Operating Instructions
The vacuuming of glowing em-
bers and of materials that are
combustible, explosive or harm-
ful to health is prohibited.
There is a risk of injury!
•
Place the equipment on a level sur-
face that is not heat sensitive.
•
Always use the suction tube for vacu-
uming. Hold the suction tube at a dis-
tance of approx. 1 cm above the ash.
•
Vacuum only cooled ash at less than
40°C.
•
When vacuuming, keep checking the
metal container and suction hose for
rises in temperature.
•
In the event of a rise in temperature,
switch off the equipment and discon-
nect at the plug. Place the equipment
outside and monitor it as it cools.
•
During breaks, you can place the suc-
tion hose (
8
6) In position "I"
6) In position "0"
12) in the accessory
holder (
2) on the container lid.
•
Always use the carry handle (
transporting the equipment.
•
The metal container may be filled to
no more than half, so the pleated filter
always remains clear.
•
Empty the container outside in order
to avoid mess (see "cleaning/mainte-
nance").
•
Clean the pleated filter (
"cleaning/maintenance") if the suction
performance deterio rates or when the
inspection window blockage indicator
(
3) on the container lid turns red.
Cleaning/Maintenance
Pull out the mains plug.
Danger of electric shock.
Never hose the appliance down
with water. Never use aggres-
sive cleaning agents or sol-
vents. This could damage the
appliance.
General Cleaning Work
Clean the equipment after each use:
•
Carry out cleaning outside in order to
avoid mess.
•
Take off the container lid (
empty the metal container (
Clean the metal container with water
and allow it to dry.
•
Clean the wire filter basket and the
pleated filter (see below).
Cleaning the Wire Filter Bas-
ket and Pleated Filter
Replace the pleated filter if it is
worn, damaged or heavily soiled
(see "replacement parts").
9) for
13) (see
5) and
10).