12 Cleaning
Frequency will depend on the type of
environment in which the product is used.
12.1 Cleaning the glass
The product must be cleaned with water or with
another liquid detergent that does not create a
hazard.
12.2 Cleaning the product
The cleaning of the product should be
carried out according to the instructions
in this chapter in order to prevent
accumulation of electrostatic charges.
The outside surface of the product must
never be covered in more than 5 mm of
dust.
The device should be cleaned using a damp cloth;
compressed air must not be used.
13 Information on disposal
and recycling
The European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment (WEEE) mandates
that these devices should not be disposed of in the
normal flow of municipal solid waste, but they should
be collected separately in order to optimize the
recovery stream and recycling of the materials that
they contain and to reduce the impact on human
health and the environment due to the presence of
potentially hazardous substances.
The symbol of the crossed out bin is marked
on all products to remember this.
The waste may be delivered to appropriate collection
centers, or may be delivered free of charge to the
distributor where you purchased the equipment at
the time of purchase of a new equivalent or without
obligation to a new purchase for equipment with size
smaller than 25cm .
For more information on proper disposal of these
devices, you can contact the responsible public
service.
MNVCMMX_1821_EN
14 Troubleshooting
Contact an authorized support centre if the
problems listed below persist or you have
any other issues that are not described
here.
PROBLEM
The product does not go on.
CAUSE
Wrong cabling, broken fuse.
SOLUTION
Make sure the connections are
correct. Check continuity of the
fuse and, if faulty, replace it with the
indicated model.
15 Technical data
15.1 Mechanical
AISI 316L stainless steel construction
External shot peened and electro-polished surfaces
Sunshield
Supports for wall, ceiling or parapet installation
Unit weight:
• 6.5kg (14.3lb) (housing + mounting bracket)
• 8.5kg (18.7lb) (housing + bracket with 4m (13ft)
multi-polar cable shield)
15.2 Cable glands
Cable entry: 1 hole, 1/2" NPT
Cable gland Ex d 1/2"NPT (with pre-installed cable
only)
15.3 Housing's window
Material: Thermally tempered glass
Usable diameter: 73.5mm (2.9in)
27