11 Maintenance

Maintenance must be carried out by
personnel trained to operate on electrical
circuits.

11.1 Fuses replacement

Maintenance must be performed with the
power supply disconnected and the circuit-
breaker open.
If necessary, replace the fuse illustrated in figure (7.3
Connector board description, page 14).
FUSES REPLACEMENT
Voltage
Fuse F1
24Vac, 50/60Hz
F 6.3A H 250V 5x20
120Vac, 50/60Hz
F 6.3A H 250V 5x20
230Vac, 50/60Hz
F 6.3A H 250V 5x20
Tab. 6

12 Cleaning

12.1 Window and plastic cover
cleaning
Avoid ethyl alcohol, solvents, hydrogenated
hydrocarbide, strong acid and alkali. Such
products may irreparably damage the
surface.
We recommend using a soft cloth with neutral soaps
diluted with water or specific products to clean the
glasses lenses.
MNVCUPKHXL_1625_EN
13 Disposal of waste
materials
Your product is designed and manufactured with
high quality materials and components which can be
recycled and reused.
This symbol means that electrical and electronic
equipment, at their end-of-life, should be disposed of
separately from your household waste.
Please dispose of this equipment at your local
Fuse F2
Community waste collection or Recycling centre.
T 8A H 250V 5x20
In the European Union there are separate collection
systems for used electrical and electronic products.
T 4A H 250V 5x20

14 Troubleshooting

T 2A H 250V 5x20
PROBLEM
CAUSE
SOLUTION
PROBLEM
CAUSE
SOLUTION
This symbol mark and recycle system
are applied only to EU countries and not
applied to the countries in the other area of
the world.
Contact an authorized support centre if the
problems listed below persist or you have
any other issues that are not described
here.
The product does not go on.
Wiring error, blown fuse.
Make sure the connections are
correct. Check the continuity of the
fuses and replace them with the
indicated models should they fail.
During start-up the pan & tilt is
disabled.
Air temperature is very low.
Wait until the end of the pre-heating
procedure.